| HS Code | 182536 |
| Product Name | 19mm High Tensile Fibrillated PP Mesh Fiber for Precast Concrete Elements |
| Material | 100% Virgin Polypropylene |
| Polymer Type | Polypropylene (PP) |
| Fiber Type | Fibrillated Mesh |
| Length | 19 mm |
| Equivalent Diameter | 20–50 µm |
| Aspect Ratio | 380–950 |
| Tensile Strength | 400–600 MPa |
| Elastic Modulus | 3.5–5.0 GPa |
| Melting Point | 160–170 °C |
| Density | 0.91 g/cm³ |
| Alkali Resistance | Excellent |
| Acid Resistance | Excellent |
| Water Absorption | Negligible (<0.01%) |
| Dosage Rate | 0.6–1.8 kg/m³ |
| Application | Precast Concrete Elements |
| Color | Natural White / Gray |
| Electrical Conductivity | Low / Non-conductive |
| Thermal Conductivity | Low |
| Uv Resistance | Good with UV Stabilization |
As an accredited 19mm High Tensile Fibrillated PP Mesh Fiber for Precast Concrete Elements factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | 19mm High Tensile Fibrillated PP Mesh Fiber for Precast Concrete Elements: packed in 20 kg moisture-resistant woven bags, 40 bags per pallet. |
| Container Loading (20′ FCL) | 20′ FCL loading: 19mm high tensile fibrillated PP mesh fiber for precast concrete, palletized, shrink-wrapped, and secured for safe ocean shipment. |
| Shipping | Shipped in 20kg moisture-resistant PP woven bags, stacked on pallets and shrink-wrapped. Transported by sea, truck, or rail in standard dry containers. Store indoors, away from direct sunlight and moisture. Non-hazardous, no special handling required. Keep packaging intact during transit. Ensure clean, dry conditions. Pallets secured to prevent shifting. |
| Storage | Store in a cool, dry, well-ventilated warehouse in original sealed packaging. Place on pallets off the floor, away from moisture, direct sunlight, UV, heat, flames, and strong oxidizers. Avoid crushing, puncturing, or overstacking bags. Keep clean and dust-free, use FIFO rotation, and do not smoke nearby. |
| Shelf Life | Indefinite when kept dry in original packaging, protected from UV, moisture, and contamination; no expiry under recommended storage conditions. |
In tunnel lining segment production, the 19 mm high-tensile fibrillated polypropylene mesh fibre is introduced into a low-water-cement-ratio concrete where design acceptance is controlled not by cube compressive strength alone but by the post-crack residual flexural tensile relationship measured as f_R1k and f_R3k at 0.5 mm and 2.5 mm crack mouth opening displacement in accordance with EN 14651:2005+A1:2007. The fibre is CE marked under EN 14889-2:2006 Annex ZA, with the manufacturer’s declaration of tensile strength, elastic modulus, elongation at break, alkali resistance, and chloride content forming part of the precast plant’s production control plan under EN 13369:2018 and EN 206:2013+A2:2021. Published technical submissions for segmental linings set the dosage range at 3.5 kg/m³ to 6.0 kg/m³, corresponding to a volume fraction of 0.38 vol% to 0.66 vol% at a polypropylene density of 0.91 g/cm³; at the upper band, a high-range water reducer is required to hold a target slump of 90–130 mm without increasing water-cement ratio beyond the specified 0.30–0.35. Production on mechanised carousel lines using 2.0–3.5 m³ twin-shaft compulsory mixers requires the fibre to be dosed after coarse aggregate charging and before water addition, because aggregate shear opens the fibrillated mesh bundles; automated weight-controlled dosing is preferred over manual bag dumping due to batch-to-batch residual strength variation of less than 8% under automated conditions versus local fibre balling when manual addition is used. Mixing after fibre introduction is limited to 60 seconds, since longer high-shear planetary mixing can twist fibres into agglomerates that block the skip hoist and create local void defects in the finished ring. External vibrators attached to the segment mould operate at 6000–9000 vpm in 15–25 second intervals to avoid fibre segregation near gasketed joint faces, while steam curing follows a holding temperature of 55–65°C for 6–8 hours; demoulding is not initiated below 15 MPa compressive strength because early stripping cracks along the longitudinal joint are not offset by the fibre’s crack-arresting function. End products include tapered universal rings, rectilinear cross-passage segments, key segments, and shaft lining rings for TBM-driven road, rail, water, and utility tunnels. The fibre is not a direct replacement for steel reinforcement in the jack shoe bursting zone, where splitting stresses require reinforcement or project-specific nonlinear finite-element validation.
The wet-cast manhole and drainage structure process exposes the 19 mm fibre to concrete with a higher initial slump and a greater sensitivity to stripping damage than dry-cast pipe, and the dosage band of 4.0 kg/m³ to 6.5 kg/m³ is set by the required restrained shrinkage crack control in 150–250 mm thick vertical walls, not by structural load capacity. Conformity assessment is carried out under EN 1917:2002 for precast concrete manholes and inspection chambers, read with EN 206:2013+A2:2021 and EN 13369:2018, which requires the fibre type and dosage to be recorded in the production control plan and traceable to EN 14889-2:2006. In vertical battery moulds with internal core formers and external jackets, the concrete is discharged from a 1.0–2.0 m³ skip through a 200 mm tremie and compacted with 50–60 mm internal poker vibrators at 12,000–14,000 vpm for 10–15 second insertions, because external vibration alone does not consolidate concrete around corbel openings, pipe entries, and joint overlaps. Stripping is commonly carried out at 16–20 hours when compressive strength reaches 12–15 MPa; production-scale observations indicate that insufficient dispersion of fibrillated fibre in the vertical wall can cause local fibre-rich pockets that tear during ejector pin stripping, so the mixer is run for 75 seconds after the final fibre addition. Terminal products include 1200 mm and 1800 mm diameter riser sections, conical reducers, shallow base units, catch basins, and stormwater junction chambers. The fibre controls restrained drying shrinkage and edge spalling in these units but does not prevent hydrogen sulfide biogenic acid attack in sewer manholes; plants handling aggressive leachate must separately specify sulfate-resisting cement or an impermeable barrier coating under EN 206 exposure classes XA3 and XD3.
Below 5.5 kg/m³, dry-cast pipe production uses the 19 mm fibre in a zero-slump concrete with a water-cement ratio of 0.26–0.32 and a manufacturer-recommended dosage of 2.8 kg/m³ to 5.5 kg/m³, while wet-cast box culvert production operates at 3.5 kg/m³ to 5.0 kg/m³ because the higher paste content can disperse the fibrillated mesh without tearing the fresh concrete during immediate stripping. The governing standards are EN 1916:2002 for concrete pipes and ASTM C1433/C1433M-20 for precast reinforced concrete box sections, with the fibre specified under ASTM C1116/C1116-23 Type III synthetic fibre-reinforced concrete or EN 14889-2:2006 depending on the market. In packerhead or bidirectional rollerhead machines, the low water content means the fibrillated fibre must be added to the aggregate stream in a pre-opened condition; if bundles remain intact, they create visible voids and surface tearing after immediate demoulding. Plant trial records from dry-cast pipe production show that when the dosage exceeds 5.5 kg/m³, the packerhead current draw increases by 12–15% and water absorption rises from 4.8% to 7.1%, indicating that excessive fibre volume obstructs the transfer of compaction energy through the packerhead rollers. Vibration times are set at 6–10 seconds per metre of pipe length, and the pipe is stripped onto the floor immediately after forming; the concrete must have enough green strength to avoid deformation between the reinforcing cage and the fibre-rich matrix. Terminal products are circular storm culverts, perforated underdrains, jacking pipes, box culvert sections, and transition wing walls. The macro-synthetic fibre is not credited for three-edge bearing strength or pipe class capacity; structural resistance remains governed by the reinforced concrete section and the pipe class defined in EN 1916:2002 or ASTM C1433/C1433M-20.
Architectural precast cladding production places the 19 mm fibre in the backup concrete of single-skin or sandwich panels at 1.8 kg/m³ to 3.0 kg/m³, a dosage band selected for crack control around openings, rebates, and thin returns rather than for structural post-crack capacity. Conformity is evaluated under EN 14992:2012 for precast concrete wall elements, supported by the common production control requirements of EN 13369:2018; the workability class is validated by EN 12350-8 slump-flow and EN 12350-12 J-ring passing ability when a self-consolidating concrete with a slump flow of 650–700 mm is used. In steel or fibreglass panel moulds, a 25–50 mm fibre-free face mix is placed first, and the fibre-containing backup mix is poured behind it; this prevents fibre shadows and visible fibre protrusion above 1.5 mm after acid etching, sandblasting, or polished surface treatments. Where a single-layer panel is cast, low-frequency table vibration at 4000–6000 vpm is kept below 15 seconds because prolonged vibration can align fibres perpendicular to the mould face and create a rough surface that fails the architectural tolerance in EN 14992:2012. Dosages above 3.0 kg/m³ reduce the passing ability of self-consolidating mixes through congested reinforcement around lifting anchors and window returns, and published data for this specific configuration is limited to plant-specific flow-table validation. Terminal products include sandwich wall panels, mullions, spandrel panels, column covers, cornice units, and coping elements. Fibre addition is not recommended in concrete with a cover depth below 15 mm or in polished face mixes that will be mechanically ground, because the fibrillated structure can remain visible as a surface discontinuity.
During precast highway safety barrier production, the mix is stripped within 24 hours and handled with forklift pockets or lifting anchors, so the 19 mm fibre is used to reduce edge chipping and restrained shrinkage cracking at a dosage of 4.0 kg/m³ to 7.0 kg/m³. Product conformity is assessed under EN 1317-5:2007+A2:2012 for concrete safety barriers, with the fibre specified under EN 14889-2:2006; North American projects may additionally reference the applicable state highway specification for precast concrete barrier. The concrete is a low-slump wet-cast mix with 40–70 mm slump, placed into heated steel battery moulds and compacted by high-frequency external vibrators operating at 65–80 Hz; the 19 mm fibrillated fibre reaches full dispersion within the short mixing cycle because the aggregate volume in the low-paste mix exerts high shear, but overdosing above 7.0 kg/m³ is associated with surface drag marks when the forms are removed and with a measurable increase in early hydration temperature due to higher paste demand. Terminal products include New Jersey profile, F-shape, single-slope median barrier segments, and temporary construction barrier units. The fibre is not credited for vehicle impact capacity under EN 1317-5 or for longitudinal flexural resistance; the reinforced concrete section and the crash test evidence remain the basis for containment level classification, while the fibre contributes only to durability-related crack control and spalling resistance.
Electrical vault production with knockout panels and 14 MPa stripping limits the 19 mm fibre to 3.0 kg/m³ to 5.0 kg/m³, because higher fibre volumes complicate field removal of cast-in knockouts and slow installation of conduits and ground inserts. The product is specified under ASTM C858-19 for precast concrete utility vaults, and the fibre is accepted under ASTM C1116/C1116-23 Type III or EN 14889-2:2006 when CE marking is required. Production uses collapsible steel forms with internal knockouts, conduit sleeves, and threaded ground inserts; concrete is placed with a 100–150 mm slump and compacted with internal vibration at 10,000–12,000 vpm. Steam curing at 50–60°C allows stripping at 14 MPa; at this strength the fibre reduces edge breakout around knockout panels, but field modification proceeds more slowly because the polypropylene mesh bridges microcracks and retains broken concrete fragments. Terminal products include electrical pull boxes, transformer vaults, communication splice vaults, water meter vaults, and lift station valve vaults. The fibre is not credited for structural load capacity around openings; wall reinforcement and knockout reinforcement remain in accordance with ASTM C858-19, and any field-cut opening must be re-evaluated by the project engineer.
Competitive 19mm High Tensile Fibrillated PP Mesh Fiber for Precast Concrete Elements prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618112911328 or mail to sales1@liwei-chem.com.
We will respond to you as soon as possible.
Tel: +8618112911328
Email: sales1@liwei-chem.com
Flexible payment, competitive price, premium service - Inquire now!
The 19mm High Tensile Fibrillated PP Mesh Fiber for Precast Concrete Elements is designated model HTM-F19 for specification purposes. It is manufactured from virgin polypropylene film that is mechanically fibrillated into an open mesh and cut to a nominal length of 19 mm. The fibre is classified as a Type III macro-synthetic reinforcement under ASTM C1116/C1116M-23 and falls within the polymer fibre category of EN 14889-2:2006 Class II. Because the cross-section is an expanded tape rather than a cylinder, the equivalent diameter is usually reported between 0.30 mm and 0.50 mm, producing an aspect ratio of approximately 38:1 to 63:1. The product is intended for secondary reinforcement in precast concrete elements where plastic shrinkage control, impact toughness, and post-crack residual strength are specified. Exact geometry and fibrillation pattern vary by production lot and should be confirmed against the manufacturer’s certificate of analysis.
The fibrillated mesh structure is produced by slitting and stretching a polypropylene film to create a controlled network of longitudinal filaments connected by transverse fibrils. This open-mesh geometry distinguishes the product from circular-section monofilament fibres and from fibrillated microfibres used at dosages below 0.9 kg/m³ for plastic shrinkage alone. The 19 mm length places it in the macrofibre range, where the primary hardening-state function is to bridge cracks that form after initial set and during mechanical handling.
| Property | Representative value/range | Test method / standard |
|---|---|---|
| Model designation | HTM-F19 | Manufacturer specification |
| Fibre type | High-tenacity fibrillated polypropylene mesh | Manufacturer specification |
| Nominal length | 19 mm | Manufacturer specification |
| Equivalent diameter | 0.30–0.50 mm | Manufacturer specification |
| Specific gravity | 0.91 g/cm³ | ISO 1183-1:2019 |
| Tensile strength | 550–650 MPa | ISO 2062:2009 / producer data |
| Modulus of elasticity | 4.0–9.5 GPa | Producer data |
| Melt temperature | 162–168 °C | ISO 11357-3:2018 |
| Water absorption | <0.1% | ASTM D570-22 |
| Regulatory status | REACH, RoHS Directive 2011/65/EU | Producer declaration |
The fibre is supplied in degradable paper bags of 0.5 kg, 1.0 kg, or bulk bags of 10–20 kg, suitable for direct addition at the mixer. Moisture regain is negligible; the fibre does not absorb mixing water and does not alter the effective water-to-cement ratio by fibre saturation. The product is dosed by mass, and paper-bag addition permits one-bag or multiple-bag introduction directly into the mixer without opening the bags when specified by the manufacturer. Storage should be in dry conditions below 40 °C. Prolonged outdoor storage can embrittle the packaging and the exposed fibre surface before mixing, but the embedded concrete environment is not detrimental to polypropylene.
In an extruded monofilament, load transfer across a crack is controlled largely by fibre-to-matrix friction and the geometry of any end deformation. In a fibrillated mesh, the mixing action opens the tape into a network of longitudinal strands and transverse fibrils. That network increases the specific surface area available for cement paste contact and creates multiple small bearing points along the bond length. The fibre does not rely on chemical adhesion to the matrix. In the alkaline pore solution of concrete at pH 12.5–13.5, polypropylene is inert and does not dissolve, corrode, or consume alkalinity. Pull-out resistance is therefore mechanical. Under ASTM C1609/C1609M-19 beam testing, the fibre can maintain residual loads at mid-span deflections of L/600 and L/150 when the dosage is correctly selected for the matrix strength. Published data for this specific configuration is limited; preconstruction qualification should confirm the residual strength values for the actual cementitious mix.
For precast elements produced as dry-cast or zero-slump concrete, the fibre is typically added at 2–9 kg/m³. Pipe and box-culvert applications commonly fall in the 3–6 kg/m³ range, while damage-resistant precast segments may require 6–9 kg/m³. The upper dosage is limited primarily by workability reduction and the risk of fibre balling rather than by cement chemistry. The fibre should be introduced into the aggregate stream before cement and water, preferably through a dosing unit interlocked with the aggregate weigh hopper. In a twin-shaft forced-action mixer of approximately 1.0 m³ batch capacity, the mesh opens under aggregate shear and disperses within a short mixing interval. When the fibre is added after water, plant experience indicates a higher incidence of agglomerates that survive mixing and transfer, especially in low-slump mixtures. Sand moisture in the range of 2–4% improves dispersion by reducing static surface charges, but free moisture above 6% should be corrected because it increases cohesion between fibres and aggregate particles. Published data for this specific configuration is limited, so batching sequence and mixing time must be verified in preconstruction trials.
The influence on fresh-state rheology is an increase in plastic viscosity rather than a change in free water. In wet-cast mixes, a dosage of 4 kg/m³ may reduce slump by 10–20 mm depending on aggregate packing and cement paste volume. The fibre does not entrain air; observed air-content changes are generally within testing variability. The water absorption value below 0.1% by ASTM D570-22 is negligible for batch water calculations.
Post-crack performance is normally assessed with notched beam tests under EN 14651:2012 or four-point bending under ASTM C1609/C1609M-19. The fibre changes the residual flexural strength after first cracking. Steel fibre has a high elastic modulus near 200 GPa, which enables rapid load recovery after crack initiation. A 19 mm fibrillated PP mesh fibre has a lower modulus, generally in the range of 4.0–9.5 GPa, so the crack width before full fibre activation can be larger. The fibrillated tape compensates in part by offering discontinuous debonding stages and multiple anchorage points, which reduce the smooth pull-out behaviour observed with plain monofilaments. In precast panels and pipes, this can improve edge retention and handling damage resistance at lower dosage than some monofilament products. The fibre is not a direct modulus replacement for steel fibre and should not be used as the sole reinforcement in primary load-bearing members. Primary reinforcing bars or welded-wire reinforcement remain necessary where structural capacity under design loads is required.
The matrix below compares the representative product class with steel macrofibre and an extruded PP monofilament macrofibre. Values are material-class ranges compiled from public literature, and exact model HTM-F19 values must be confirmed by the producer.
| Property | Steel macrofibre | Extruded PP monofilament | HTM-F19 fibrillated PP mesh |
|---|---|---|---|
| Density | 7.85 g/cm³ | 0.91 g/cm³ | 0.91 g/cm³ |
| Tensile strength | 1000–1500 MPa | 500–600 MPa | 550–650 MPa |
| Elastic modulus | 200 GPa | 3.5–7 GPa | 4.0–9.5 GPa |
| Corrosion in chloride environments | Susceptible unless galvanized or stainless | Inert | Inert |
| Common precast dosage | 20–40 kg/m³ | 3–6 kg/m³ | 2–9 kg/m³ |
| Bond mechanism | Hooked or deformed anchorage, high stiffness | Surface friction with limited mechanical interlock | Fibrillar network mechanical anchorage |
The density difference between steel and polypropylene means that equal-mass addition rates produce far greater fibre counts per cubic metre for the synthetic product. The fibre count contributes to crack bridging but does not overcome the modulus gap. Selection between steel and fibrillated PP mesh therefore depends on whether the governing requirement is corrosion resistance and handling toughness or high early-age post-crack load capacity.
In dry-cast pipe production, the concrete is placed into vertical or roller-head casting machines where vibration is commonly applied in the range of 50–100 Hz. Unopened fibre bundles can bridge the feed chute, reduce local compaction, and produce surface defects, so the fibre must be fully opened before the mix reaches the cast point. The preferred addition point is the aggregate weigh batcher or a dosing unit interlocked with the aggregate discharge gate. In a counter-current pan mixer of 750 L capacity, the fibre is typically introduced with the final aggregate fraction and mixed for 15–30 s before the cement slurry is added. The exact interval is site-specific, and published data for this specific configuration is limited. Fibre balls observed at the discharge door indicate insufficient shear, excessive sand moisture, or late addition. The failure mode is physical agglomeration rather than chemical degradation and can be corrected by reducing the fibre feed rate to approximately 2–3 kg per 100 kg of cementitious material or by pre-wetting the sand to control static charge.
For box culverts cast on vibrating tables, the table frequency and amplitude should be verified because the open mesh structure can affect fresh-state compaction around intricate form profiles. Fibre clustering at form corners is a known processing bottleneck; vibrating table amplitude of 0.3–0.8 mm and a fill rate that avoids mass dumping are typically required. The fibre is compatible with high-frequency external vibrators and does not settle in the same manner as steel fibre, because its density is close to that of the concrete paste.
Precast elements that use the fibre include catch basins, septic tanks, drainage channels, concrete barriers, sound walls, lightly reinforced architectural panels, and utility vaults. In wet-cast architectural panels, the fibre is added at 2–4 kg/m³ to reduce edge spalling during demolding and transport. In dry-cast pipe and culverts, higher dosages control impact cracking during yard handling and installation. Because polypropylene is inert in chloride environments, the fibre does not create rust staining, surface pop-outs, or delamination at exposed edges. It is also non-magnetic and non-conductive, which can be relevant for infrastructure that must not interfere with embedded electrical or signal systems. The melting point of the fibre is below 170 °C, so it is unsuitable for refractory concrete or autoclave curing above 160 °C. Normal precast steam curing at 60–80 °C is within the thermal stability range. The fibre should be treated as secondary reinforcement for crack control and impact toughness, not as a replacement for primary reinforcing bars in load-bearing precast sections. ACI 544.4R-18 provides guidance on fiber-reinforced concrete design and places macro-synthetic fibres in a crack-control role unless project-specific performance tests demonstrate otherwise.
Compliance documentation should include ASTM C1116/C1116M-23 Type III classification, EN 14889-2:2006 Class II requirements for tensile strength and dimensional stability, and REACH/SVHC confirmation for the supplied raw material. RoHS Directive 2011/65/EU applies to electrical and electronic equipment but is often requested in procurement specifications; the polypropylene matrix does not contain restricted heavy metals or brominated flame retardants.
Precast tunnel segments are often specified under EN 14651:2012 with a residual flexural strength at a crack mouth opening displacement of 3.5 mm in the range of 4–6 MPa at early ages to resist TBM jacking forces. Steel fibre achieves this contribution with its high modulus, whereas a 4.0–9.5 GPa PP mesh fibre may require a substantially higher dosage and may not reach the same residual load at small crack openings. Published data for synthetic fibre substitution in structural tunnel segments is limited, and current practice frequently retains steel fibre or conventional bar reinforcement when jacking forces exceed the early-age post-crack capacity of synthetic macrofibres. The 19 mm fibrillated PP mesh fibre is therefore positioned for precast elements where corrosion resistance, edge-spalling control, impact toughness, and crack-width control govern, rather than for primary load-bearing segments under high early-age structural demand.